logo
Qingdao Yilan Cable Co., Ltd.
ইমেইল sales3@holdonecable.com টেলি 86-- 19026815676
বাড়ি > পণ্য > এক্সএলপিই অন্তরক কেবল >
BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation

BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation

উৎপত্তি স্থল চীন
পরিচিতিমুলক নাম QINGDAO YICABLE CABLE
সাক্ষ্যদান CE/IEC/KEMA/VDE
পণ্যের বিবরণ
কন্ডাক্টর উপাদান::
তামা, IEC60228
কন্ডাক্টর আকার::
1 মিমি 630 মিমি পর্যন্ত বিজ্ঞপ্তি
নিরোধক::
এক্সএলপিই (ক্রস লিঙ্কযুক্ত পলিথিন), আইইসি 60502
বাইরের খাপ::
পিভিসি, আইইসি 60502
রেটেড ভোল্টেজ ইউও / ইউ (উম)::
600 / 1000V, BS5467
ইনস্টলেশন প্রকার::
আউটডোর ডাইরেক্ট দাফন
বিশেষভাবে তুলে ধরা: 

xlpe electrical cable

,

cross linked polyethylene cable

Payment & Shipping Terms
ন্যূনতম চাহিদার পরিমাণ
200 মি
মূল্য
USD 1-299 Per Meter
প্যাকেজিং বিবরণ
আয়রন-কাঠের ড্রাম বা পুরো কাঠের ড্রাম
ডেলিভারি সময়
8-15 দিন
পরিশোধের শর্ত
এল / সি, টি / টি, ওয়েস্টার্ন ইউনিয়ন, মানিগ্রাম,
যোগানের ক্ষমতা
প্রতি মাসে 100km
পণ্যের বিবরণ

BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV Used for Fixed Installation

 

Cable Application

 

Cu/XLPE/PVC/AWA/PVC power cable may be used for fixed installation indoors and outdoors in cable ducts or directly in the ground.

Technical Information

Conductor Material: Copper, IEC60228
Conductor Shape: 50mm² up to 400mm² Circular
Conductor Flexibility: Stranded class 2
Outer Sheath: PVC, IEC60502
Inner Sheath: PVC, IEC60502
Insulation: XLPE (Cross-linked Polyethylene), IEC60502
Armour Type: Aluminium wires
Colour: Black
Lead Free: Yes
Rated Voltage Uo/U (Um): 600/1000V, BS5467
Installation Temperature: Minimum: 0°C Maximum: 60°C
Installation Type: Outdoor Direct burial
Operating Temperature: Minimum: -15°C Maximum: 90°C
Short-circuit Maximum Conductor Temperature: 250°C
Flame Retardant: IEC 60332-1 and BS EN 50265-2-1
Bending Radius: 50mm² up to 1000mm² = 6 x Ø

Rated voltage:0.6/1kV Low Voltage
Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0 OC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single core without armor
15 x cable O.D for multi core without armor
15 x cable O.D for single core with armor
12 x cable O.D for multi core with armor

Standards: International: IEC 60502, IEC 60228, (IEC 60332-3 for FR-type only)
China: GB/T 12706, (GB/T 18380-3 for FR-type only)
Other standards such as BS, DIN, VDE and ICEA upon request

Installation

1. The installation temperature should not over 20℃, If the ambient temperature is lower than 0℃, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installation, the cable should with stand voltage test for 15min. 3.5kv D.C.